Work order completion triggers

Every work order has a Completion Trigger that controls how it moves from In Progress to Completed. Set it in the work order form under Schedule & Completion.

The three options

Trigger

When the work order closes

Best for

Manual (default)

Only when a user explicitly marks it complete

Most workflows — gives you a deliberate close gate

Finish Step

Automatically, once every production step has reached its planned quantity (skipped steps count as done)

Short, simple runs where auto-close is fine

Receipt

When someone clicks Receive on the work order after finished goods arrive at the destination

Co-manufacturing runs where receiving is the natural end

Manual (recommended for most teams)

The work order stays In Progress until someone clicks Complete on the work order page. Use this when you want a review after the last batch is reported, or when draft assembly orders still need confirming.

Finish Step

The work order closes as soon as every step's produced quantity meets or exceeds its planned quantity. Work orders with no steps never auto-close.

Receipt

When the trigger is Receipt and the work order is In Progress, a Receive button appears on the work order page. Click it when the finished goods arrive at the destination warehouse. Luminous records the receipt and completes the work order.

Changing the trigger later

Click Edit on the work order and choose a different option under Completion Trigger. You can do this on Draft, Planned, and In Progress work orders. The current trigger is shown in the Details panel on the work order page.

Setting the default for new work orders

An admin can set this under Settings → Inventory → Work orders → Default completion trigger. New work orders start with this trigger, including ones created through the API that don't send one. Existing work orders aren't changed, and the setting affects everyone in your organization. If it's never been set, the default is Manual.